Excel calculation based on user input from dropdown fields


We are using Excel 2003 but can upgrade if necessary. We need to compute (or lookup) a value based on two inputs. Both inputs will be Excel dropdown boxes.


The first one will have values 6, 9, 12, 16, 20. The second dropdown has 6x6, 10x10, 20x20.


How can we lookup the corresponding value and place the result into a separate cell?



enter image description here




Answer



It doesn't need to be quite that complex. Take for example the following.


Screen print of inputs and data table



  1. Select your column headers and name them Input1. (Range E1:I1 in the example.)

  2. Select your row headers and name them Input2. (Range D2:D4)

  3. Select your data and name it Data. (Range E2:I4)

  4. Use data validation to get the dropdowns.

    • Select cell B2 and click on Data - Data Validation.

    • Set Validation criteria Allow to List and Source to =Input1

    • Do whatever you want for Input Message and Error Alert. (I turned them off.)

    • Repeat for your 2nd input. (cell B3 gets source =Input2)



  5. In your Result cell, type in this formula =INDEX(Data,MATCH(B3,Input2,0),MATCH(B2,Input1,0))


The formula works as follows:


MATCH(lookup_value, lookup_array, [match_type])


MATCH is sort of similiar to VLOOKUP except that instead of returning a cell/cell value it returns the relative position of the lookup_value within the lookup_array. Using it on the Input1 range returns the relative column position while using it on Input2 returns the relative row. Setting match_type to 0 tells Excel to only return the exact match.


INDEX(reference, row_num, [column_num], [area_num])


INDEX is returning the cell in Data found at the referenced row of Input2 and referenced column on Input1.


Note: In Excel 2010 (I'm not sure about earlier versions) the data table doesn't even need to be on the same worksheet as your Input and Result cells.


Comments

Popular Posts

How do I transmit a single hexadecimal value serial data in PuTTY using an Alt code?

I am trying to sent a specific hexadecimal value across a serial COM port using PuTTY. Specifically, I want to send the hex codes 9C, B6, FC, and 8B. I have looked up the Alt codes for these and they are 156, 182, 252, and 139 respectively. However, whenever I input the Alt codes, a preceding hex value of C2 is sent before 9C, B6, and 8B so the values that are sent are C2 9C, C2 B6, and C2 8B. The value for FC is changed to C3 FC. Why are these values being placed before the hex value and why is FC being changed altogether? To me, it seems like there is a problem internally converting the Alt code to hex. Is there a way to directly input hex values without using Alt codes in PuTTY? Answer What you're seeing is just ordinary text character set conversion. As far as PuTTY is concerned, you are typing (and reading) text , not raw binary data, therefore it has to convert the text to bytes in whatever configured character set before sending it over the wire. In other words, when y...

linux - Extract/save a mail attachment using bash

Using normal bash tools (ie, built-ins or commonly-available command-line tools), is it possible, and how to extract/save attachments on emails? For example, say I have a nightly report which arrives via email but is a zip archive of several log files. I want to save all those zips into a backup directory. How would I accomplish that? Answer If you're aiming for portability, beware that there are several different versions of mail(1) and mailx(1) . There's a POSIX mailx command, but with very few requirements. And none of the implementations I have seem to parse attachments anyway. You might have the mpack package . Its munpack command saves all parts of a MIME message into separate files, then all you have to do is save the interesting parts and clean up the rest. There's also metamail . An equivalent of munpack is metamail -wy .

ubuntu - Why does my USB hdd returns SG_IO: bad/missing sense data?

I am able to boot and run commands from external USB hdd; the message in question appears for about 45 seconds then booting continues. GRUB2 is installed on internal HDD. When choosing to boot directly to /dev/sdb the message doesn't appear, however boot time is about the same as booting to internal HDD. /dev/sdb: Timing cached reads: 1018 MB in 2.00 seconds = 508.97 MB/sec Timing buffered disk reads: 80 MB in 3.03 seconds = 26.37 MB/sec pfeiffep@de:~$ sudo hdparm -i /dev/sdb /dev/sdb: SG_IO: bad/missing sense data, sb[]: 70 00 05 00 00 00 00 10 00 00 00 00 20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 HDIO_GET_IDENTITY failed: Invalid argument Gparted correctly identifies the drive as SAMSUNG MP0402H. Any ideas how to remedy the HDIO & SG_IO messages?

Desktop reboots itself on sleep or hibernate

I have been using an ASUS M2NPV-VM motherboard for main home desktop workstation, operating Windows Vista x64. This computer has right from day one not been able to enter hibernate or standby; after Windows performs its final actions and brings the machine down, it would automatically revive itself for a reboot. Updating to the second latest BIOS (1201)has not helped (the latest BIOS revision would induce video refresh problems rendering it unusable). I have been reading related discussions on incidents similar to mine to no avail of a true workable solution. They appear to be more speculative guesses rather than actual knowledge on the inner workings of motherboard hardware. Does anybody have any electronic engineering experience on PC energy-saving standards to provide a more informed opinion how to go about getting this to work? More stories: this motherboard could not even reboot properly the first thing i used it. It was due to refresh rate of the onboard GPU, which had no influe...